Like Halgan’s other grease traps, the Modular S Series Grease Trap is upgradable for future expansion and can be installed in a line. It’s also able to be installed in ground, above ground, or on a stand. The same compact, lightweight and durable materials are utilised for the matching Surge Control Design.
What sets this grease trap apart from the standard series is the way the design incorporates features to maximise performance as well as allow for easier servicing. The Modular S Series Grease Trap has a patented service channel design. The shape of the system captures solids, oils and grease in this service channel, which has a 76mm connection for remote suction line connection. The remote suction can minimise disruption and odours during servicing, meaning business can carry on as usual.
Certification
Halgan’s Modular S Series Grease Traps have achieved AS – NZS 1546.1 Certification, making us the first pre treatment manufacturer in Australia to do so. Halgan also works with Standards Australia WaterMark Certification and the Water Services Association of Australia. By having independent appraisals completed by these organisations, we are assured our products reach the appropriate standards, allowing us to work towards more environmentally sound solutions such as the Modular S Series Grease Trap.
Specifications for all products, including the Modular S Series Grease Trap, can be found at our catalogue page grease trap. CAD and Revit drawings are also available for your benefit.
Thank you for contacting us!
We will get back to you shortly.
Use our sizing calculator to discover which Halgan S series is the best size for your business.
For each fixture, enter in the quantity you have and flow rate where required. Make sure you have the manufacture's guide handy for these. Once you've gone through the list of fixtures, you'll see a total of litres per hour which correlates to the size of the passive grease treatment you need.
Fixture | Flow Rate (L/h) | Quantity | Subtotal (L/h) |
---|---|---|---|
Dishwasher – small (under bench) | |||
Dishwasher – medium (upright) | |||
Dishwasher - tunnel feed | Use manufacturer’s peak flow rate per hour x 3 | ||
Dishwasher - large (>1 outlet) | Use manufacturer’s peak flow rate per hour x 3 | ||
Glass washing machine | |||
Glass washer - tunnel feed | Use manufacturer’s peak flow rate per hour x 3 | ||
Sink - utility / pot per outlet connected separately to drain (depth greater than 300mm) | |||
Sink – single bowl (depth up to and including 300mm) | |||
Sink – double bowl (depth up to and including 300mm fixture pair connection) | |||
Tundish - condensate (refrigerator / freezer condensate) | |||
Tundish - other (except refrigerator condensate) | |||
Grease canopy (water cleaned) | |||
Hand basin | |||
Steamer roast oven / Combi oven | 1000 L or 3000 L grease arrestor minimum size for high use combi ovens (i.e. supermarkets, fast food chains). | ||
-- Number of racks | |||
Electric or gas /steamer cooker / kettle | |||
Ice cream machine soft serve | |||
Noodle cooker | |||
Potato peeler (small kitchen application) | |||
Rotisserie rack | |||
Bain Marie - water heated | Use maximum capacity of the apparatus x 3 | ||
Bin wash | No Arrestor Required | ||
Floor waste / bucket trap / grated strip drain | 50 L/hr for every 50m2 of floor area, or part thereof. Add allowance for any listed connected apparatus | ||
Sealed floor waste gully | |||
Wok burner –dry | 30L per water arm | ||
Wok burner –wet | Use manufacturer’s peak flow rate per hour x 3 | ||
TOTAL LITRES PER HOUR |
*Sizing is calculated using QUU sizing guidelines